Resuscitator KRE-A100 is an auto-clavable, hand held, emergency device intended for pulmonary resuscitation. Inbuilt pressure relief valve minimizes the risk of over pressure. Transparent bag for complete internal visibility. Made of durable, firm and flexible material. Substantial range of reservoir volume. Easily detachable for cleaning and disinfecting.
Type | Neonatal |
Stroke volume | 150 ml |
Resuscitator volume | 250 ml |
Bag reservoir volume | 600 ml |
Pressure | 40 cmH2O |
Patient weight | ≤ 10 kg |
Dead space (patient valve) | 7 ml |
Dimensions (L × D) | 225 × 85 mm |
Used in emergency medical services, crash carts and critical care to provide positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated.
Infant Incubator is used in neonatal care to regulate temperature and humidity conditions inorder to maintain a controlled environment for neonates. Medical Equipment Infant Incubator range features accurate temperature and humidity monitoring and regulation, accessible outer shell with easy-to-clean surfaces, spacious adjustable baby bed.
Control System : Air-temp control, Skin-temp control & Humidity control
Display : LED display
Control System : Air-temp control & Skin-temp control
Display : LED display
Infant Warmer is an essential equipment in neonatal care to regulate radiant temperature, often used in maternity wards for newborn babies to provide them with controlled weaning temperature according to medicals standards and practice. Medical Equipment Infant Warmer range provides a wide range with bed tilt, sensor-based temperature control, alarms and other user-oriented features for effective clinical workflow.
Control System : Microprocessor based temperature control system
Control Modes : Preheat, Manual and Skin-temp mode
Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Medical Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.
Light Source : 8 Blue LED lights
Wavelength : 450 to 475nm
Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Medical Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.
Waveform : Biphasic
Energy Sequence : 150 J, 200 J
Medical Equipment offers a wide range of superior quality portable and mini-sized Infusion pumps, suited for a wide range of applications in hospitals wards and clinics. Infusion pumps are medical devices capable of delivering a controlled dosage of fluidized drugs, enteral nutrition into a patient's circulatory system.
Channel : Single channel infusion
Volume (VTBI) : 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Channel : Single channel infusion
Infusion Volume : 0 ml ~ 9999 ml ( 0.1ml increment)
Medical Equipment presents a wide range of pneumatically driven and electronically controlled ventilators that assist the breathing of adults and paediatric patients alike. Medical Equipment Ventilators feature configurable loops and trends, invasive and non-invasive ventilation, adult and paediatric ventilation, high-flow oxygen therapy. They are applicable in hospitals, clinics, private practices and ambulances.
Tidal Volume : 20 ml ~ 500 ml
Standard Ventilation Mode : VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH
Tidal Volume : 10 ml ~ 300 ml
Standard Ventilation Mode : CMV, IMV, CPAP, Manual
Tidal Volume : 20 ml ─ 2500 ml
Configurations : Trolley or Ceiling Pendant
Tidal Volume : 0 ml – 1500 ml
Gas Supply : O<sub>2</sub>, 0.28 to 0.6 MPa
Medical Equipment offers a wide selection for Syringe Pump. Our Syringe pump systems are programmed with memory based on safety limits of drugs to deliver intermittent infusion for a specific duration according to associated safety and performance standards.
KVO Rate : 0.1 – 5ml/h (steps : 0.1ml/h)
Injection Compliance : Adaptable for 5 syringe sizes
Channel : Dual channel infusion
Volume (VTBI) : 0.1 ml – 1999.9 ml
Medical Equipment offers a wide selection for Blood or Infusion warmer. Our infusion warmers are designed for leak-proof optimized warming with self-monitored temperature test and alarms as per associated safety and performance standards.
Temperature Range : 37°C to 42°C
Temperature Accuracy : ± 0.5°C
Temperature Range : 37°C to 42°C
Temperature Accuracy : ± 1.0°C